Products for Industry

Dry Sterilizer (Laboratory use) SK811

Item Code : 212912
Model : SK811

SK811

Cable Port Φ33㎜

Temperature Rising Curve

Method

Dry Sterilizer (Laboratory use) (SK811)

Product Summary

Dry heat sterilization with independent overheat prevention device

Features of Dry Sterilizer (Laboratory use) (SK811)

Features
Programmable
Features
High precision controller with improved
display visibility and operability
Features
Standard equipped with calibration offset,
lock function, power recovery mode,
power on and operation time accumulation,
calendar time, accumulation power
consumption monitoring, total CO2 emission,
and heat output, save and access
operator setting information
Features
Maximum 99 steps, 99 patterns, repeat
operation
Features
Easy sample data collection with cable port
Safety features
Standard equipped with self diagnostic
functions, independent overheat prevention
device and earth leakage breaker

Specifications

Specifications

Item Code 212912
Model SK811
Circulation method Forced convection
Temp. setting range Room temp. +10~210°C
Temp. control accuracy ±1℃(at 210℃)JTM K05
Temp. fluctuation 2℃(at 210℃)JIS
Temp. rising time Approx. 60min.
Interior / Exterior material Stainless Steel / Chrome free electrogalvanized carbon steel sheet coated with chemical-proof baked-on finish
Insulation Material Glass wool
Heater SUS 2.4kW
Sensor K type Thermocouple
Fan type / Fan motor Sirocco Fan / Condenser type motor 30W
Cable port I.D. 33mm (right side)
Exhaust port I.D. 33mm×2 (back side)
Temperature control PID control by microprocessor
Temperature display Temp. display: Green 4-digit LED digital display (increment: 1°C)
Timer 0 min~99 hrs 59 min (increment: 1 min. or 1 hr.)
Operation function Fixed temperature, Auto start, Auto stop, Quick auto stop, Program (99 steps, 99 patterns, Repeat operation function)
Additional function Power on and operation time accumulation function (up to 65535 hours), Calendar time (24 hours), Calibration offset,
Safety device Self-diagnostic functions (Sensor failure, SSR short circuit, Heater failure, Main relay contact failure, Automatic overheat prevention),
Internal dimensions(W×D×H mm) 600×500×1000mm
External dimensions(W×D×H mm) 710×650×1640mm
Remarks(dimensions) Internal capacity 300L
Power Source AC220V 12A
Weight 108kg

Maintenance and warranty


Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
External dimensions do not include protrusions.



Optional items

Stainless punching metal shelf
Cable port (ODK32)
Cable port (ODK34)
NO IMAGE
External communication adapter set (OIN90)
NO IMAGE
External communication terminal (RS485) (ODS16)
NO IMAGE
Temperature Detection Terminal (4-20mA) (ODS18)
NO IMAGE
External alarm output terminal (ODS22)
NO IMAGE
Time-up output terminal (ODS24)
NO IMAGE
Operation signal output terminal (ODS26)
NO IMAGE
Event output terminal (ODS28)

Same series products

Dry Sterilizer (Laboratory use) (SK401)
Dry Sterilizer (Laboratory use) (SK601)
Dry Sterilizer (Laboratory use) (SK801)