Product Summary
Water cooling heat dissipation system (CTW type) and air cooling heat dissipation system (CTA type) are available.
Features of Cooling Water Circulator (Externally Opened Circulation, Peltier Cooling) (CTA802S)
- Features
- Integrated type (CTW402 / 802, CTA402 / 802) and Separated type (CTW402S / 802S, CTA402S / 802S) are selectable.
- Features
- External open constant temperature water circulator with separate cooling/heating assembly and power control assembly enables to control the constant temperature water precisely. It uses a Freonfree cooling system.
- Features
- The RS485 communication function is provided as standard and can be centrally managed from a PC.
Specifications
Specifications
Item Code | 221645 |
---|---|
Model | CTA802S |
System | Separated type, Air cooled electronic system, External open circulation |
Operating temperature range | 0 to +70℃ |
Temp. adjustment accuracy | ±0.1℃ |
Cooling capacity | 163 kcal/h (189W) |
Performance pump capacity (50 Hz) Maximum flow ratemax. flow (50/60Hz) | 11 L/min |
Performance pump capacity (50 Hz) Maximum discharge pressure | 78.4kPa |
Timer function | 1 min to 99 hrs 50 min, 100 to 9999 hrs (with time/clock switching function) |
Operation function | Fixed temp., Auto-start, Auto-stop, Quick auto stop, Program (Max.99 steps, step separate,repeat, gradient), Program auto start |
Other functions | Self diagnostics, Calibration offset, External temperature sensor switching, Power failure recovery mode, RS485 external communication, Alarm output terminal, Key lock, Display the amount of Power consumption, Operation guidance |
Safety unit | Over current electric leakage breaker, Abnormality detection (Temp. sensor, Overheat, Peltier, Temp. upper / lower limit, Power supply, Internal communication, Memory) |
Material of cooling/heating unit liquid contact part | Stainless steel (SUS304) |
Circulation port nipple diameter | O.D.: 12.7mm |
Number of thermo module | 8 |
Accessories | Circulation heat insulation hose (ID 11.5mm 1m×2pcs.), Heat radiation water hose (ID12mm 3m×1pc., CTW only), Stacking support (Separated type only) |
External size(mm) Separated type (-S) | W361×D410×H265, W291×D342×H195 |
Weight Separated type (-S) | 27kg, 10 kg |
Remarks(dimensions) | Separated type |
Power Source |
AC115V
6A
Single-phase with step down transformer |
Weight | 00kg |
Maintenance and warranty
Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
External dimensions do not include protrusions.