Custom Equipment
DP Series (Large Capacity)
Main Specifications
Specifications
| Product Code | Model | Heater | Accessories Shelf plate | Safety countermeasures | Additional functions | Other display | Temp display method | Temp. setting method | Temp. control method | Inlet/Purge port | Exhaust port | Temp. sensor | Heater circuit control | Operation functions | Heat insulating material | Door | Exterior Material | Interior Material | Temp. adjustment accuracy | Operating pressure range | Operating temperature range | Method | Internal dimensions(W×D×H mm) | External dimensions(W×D×H mm) | Power supply | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DP1030 | DP1030 | Mica heater, 14.4kW | Punched stainless steel, 4 pcs | Self diagnosis functions(Sensor, Heater, Triac, Automatic overheating prevention), Independent overheating prevention, Key lock function, Electric leakage breaker | Calendar timer (max. 24 Hrs.), Integration time (max. 65535 hrs.), Clock, Calibration off-set, Display the amount of power consumption / CO2 discharge / Heater operation amount,Power failure recovery mode, User setting information save and recall | Temperature indicating the operation state displayed by LED | Digital display | Digital setting with UP/DOWN key | PlD control by microprocessor | RC 3/8 | NW40 | K-thermocouple (Double sensor) | Triac zero-cross control | Fixed temp., Auto-start, Auto-stop, Quick auto stop, Program (max.99 steps, 99 patterns, repeat) | Rock wool | Single swing door | Cold rolled steel plate with baked-on melamine resin finish | Stainless steel | ±1℃(at200℃) | 100 to 0.1kPa(760 to 1 Torr) | 40 to 200℃ | Vacuum drying by decompressed chamber direct heating | 1000×1000×1000mm | 1300×1280×2110mm | AC220V/380V Three-phase |
1000kg |
| 200000 | DP810 | Mica heater, 6.5kW | Punched stainless steel, 2 pcs | Self diagnosis functions(Sensor, Heater, Triac, Automatic overheating prevention), Independent overheating prevention,Key lock function, Electric leakage breaker | Calendar timer (max. 24 Hrs.), Integration time (max. 65535 hrs.), Clock, Calibration off-set, Display the amount of power consumption / CO2 discharge / Heater operation amount,Power failure recovery mode, User setting information save and recall | Temperature indicating the operation state displayed by LED | Digital display | Digital setting with UP/DOWN key | PlD control by microprocessor | RC 1/4 | NW40 | K-thermocouple (Double sensor) | Triac zero-cross control | Fixed temp., Auto-start, Auto-stop, Quick auto stop, Program (max.99 steps, 99 patterns, repeat) | Rock wool | Single swing door | Cold rolled steel plate with baked-on melamine resin finish | Stainless steel | ±1℃(at200℃) | 100 to 0.1kPa(760 to 1 Torr) | 40 to 200℃ | Vacuum drying by decompressed chamber direct heating | 800×800×800mm | 1020×1019×1850mm | AC220V 30A Single-phase |
600kg |