Natural convection oven

DXS Series

DXS200 Product Code : 212915

DXS300 Product Code : 212916

Main Specifications

Specifications

Product Code Model Heater Exhaust Port Door Temp. Control System Temp. Setting Temp. Display Timer Operation Function Operation Panel Additional Function Safety Countermeasure Circulation Type Operating Temp. Temp. Adjustment Accuracy Temp. fluctuation Temp. Distribution Accuracy Temp. gradient Max. Temp. Reaching Time Interior Material Exterior Material Heat Insulating Material Internal dimensions(W×D×H mm) External dimensions(W×D×H mm) Power supply Weight
212915 DXS200 Iron & chromium wire heater 400W SUS304, I.D. 30mm x 1 (Top Side) Chrome-free electrogalvanized steel plate with melamine resin baking finish PID control by microprocessor Digital Setting by UP/DOWN Key Digital Display by LED 0 to 999.9hrs. Fixed Temp. Operation, Automatic Start, Automatic Stop, Program Operation, Quick automatic stop Sheet key, (LED; Temperature, Timer Lamp; Heater, Abnormal Temperature) Main switch for Short Circuit Breaker Calibration Off set function, Power failure return mode Independent Overheat Prevention by Liquid Pressure Type, Individual Overheat Prevention, Heater Wire Broken/Sensor Input Alarm, Electric Leakage Breaker, Key Lock Function Natural Convection Room Temp. +5 deg.C to 210 deg.C ±1 deg.C (at 210 deg.C) ±3 deg.C (at 210 deg.C) ±10 deg.C (at 210 deg.C) 35 deg.C (at 210 deg.C) Approx. 60 min Stainless Steel Chrome-free electrogalvanized steel plate with melamine resin baking finish Rock Wool 240×250×340mm 320×340×685mm AC220V 2.1A
Single-phase with step down transformer
20kg
212916 DXS300 Iron & chromium wire heater 800W SUS304, I.D. 30mm x 1 (Top Side) Chrome-free electrogalvanized steel plate with melamine resin baking finish PID control by microprocessor Digital Setting by UP/DOWN Key Digital Display by LED 0 to 999.9hrs. Fixed Temp. Operation, Automatic Start, Automatic Stop, Program Operation, Quick automatic stop Sheet key, (LED; Temperature, Timer Lamp; Heater, Abnormal Temperature) Main switch for Short Circuit Breaker Calibration Off set function, Power failure return mode Independent Overheat Prevention by Liquid Pressure Type, Individual Overheat Prevention, Heater Wire Broken/Sensor Input Alarm, Electric Leakage Breaker, Key Lock Function Natural Convection Room Temp. +5 deg.C to 210 deg.C ±1 deg.C (at 210 deg.C) ±3 deg.C (at 210 deg.C) ±10 deg.C (at 210 deg.C) 40 deg.C (at 210 deg.C) Approx. 60 min Stainless Steel Chrome-free electrogalvanized steel plate with melamine resin baking finish Rock Wool 300×350×530mm 380×440×875mm AC220V 3.9A
Single-phase with step down transformer
30kg