Overheating Prevention Devices
TS Series
Main Specifications
Specifications
| Product Code | Model | Temp. setting system | Accessories | Exterior/interior | Safety function | Connecting system of target device | Temp. sensor/temp. sensor protective tube | Temp. sensor/temp. sensor protective tube | Overheat temp. detection | Recovery system after detecting overheat | Temp. display system | Power breaking capacity | Temp. detection accuracy | Temp. display range | Temp. setting range | External dimensions(W×D×H mm) | Power supply | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 583719 | TS101 | Digital setting with up/down keys | Sheath type K thermocouple (soaked part: 200 mm) x 1, main unit securing clamp x 1 | Chrome free electro galvanized cupper plate, chemical proof baking finish, stainless steel plat | Internal fuse & self diagnostic function (abnormal input temperature/memory error) | 3P power outlet | a-contact 250V 3A | Sheath type K thermocouple/3.2 mm dia x length of 200 mm (encapsulated in a SUS316 protective tube) | Shutting off power of the target device/alarm with a buzzer alternately displays Er07 and the sensor detection temperature on the measured temperature display | Manual (Turn POWER switch ON after returning to normal from overheating condition.) | Digital display for sensor and set temperatures | AC100V 50/60 Hz 14.5A Single phase | ±1deg.C | -200deg.C to 1300deg.C | 0deg.C to 500 deg.C | 150×210×155mm | AC115V/AC220V Single-phase with step down transformer |
3.5kg |
| 583720 | TS310 | Digital setting with up/down keys | Sheath type K thermocouple (soaked part: 200 mm) x 1, main unit securing clamp x 1 | Chrome free electro galvanized cupper plate, chemical proof baking finish, stainless steel plate | Internal fuse & self diagnostic function (abnormal input temperature/memory error) | Connection terminal block for 4P (3P) power cord | a-contact 250V 3A | Sheath type K thermocouple/3.2 mm dia x length of 200 mm (encapsulated in a SUS316 protective tube) | Shutting off power of the target device/alarm with a buzzer alternately displays Er07 and the sensor detection temperature on the measured temperature display | Manual (Turn POWER switch ON after returning to normal from overheating condition.) | Digital display for sensor and set temperatures | AC100V 50/60 Hz 30A AC200V 50/60 Hz 30A AC200V 3-phase 50/60 Hz 30A | ±1deg.C | -200deg.C to 1300deg.C | 0deg.C to 500deg.C | 150×210×155mm | AC115V/AC220V Single-phase with step down transformer |
3.5kg |