Muffle Furnaces
FP101/301/311/411 |
 |
FP101/301/311/411 have been discontinued

FP101/311 |
Temperature Range |
100deg.C to 1,150deg.C |
Temperature Control Accuracy |
±1.5deg.C ( at 1,150deg.C) |
Internal Capacity |
1.5 to 11.3 L |
|
|
 |
- Automatic start/stop, and program operation are available.
- Equipped with self-diagnosis function, a key-lock function, etc, The functions of the preservation and the determent of an incorrect operation are heightened.
- Contamination of samples is prevented due to high quality alumina ceramic hot plate and heater is not exposed in the furnace.
- Variegated options are available, including a N2 gas inlet, a predetermined elapsed time output terminal, an external alarm terminal, and an independent superheating preservation circuit.
|
Specifications |
Model |
FP101 |
FP301 |
FP311 |
FP411 |
Performance |
Operating temperature range |
100 to 1,150deg.C |
Temp. control accuracy |
±1.5deg.C(at 1,150deg.C) |
Max. temp. reaching time |
Approx.80min. |
Components |
Exterior material |
Cold rolled steel plate with baked-on melamine resin finish |
Furnace material |
Ceramic fiber |
Sensor |
R-thermocouple |
Heater |
Iron-chrome wire heater |
1.1 kW |
2.4 kW |
3.25 kW |
Exhaust port |
20 mm I.D. (upper part) |
Cooling fan |
19/16W ( 50/60Hz) |
Controller |
Temp. controller |
PID control by microprocessor |
Temp. and timer setting method |
Digital setting with jog dial |
Temp display method |
Digital display by green LED |
Operation function |
Fixed temperature operation, Automatic-start, Automatic-stop, |
Program operation (max. 16 segments) |
Additional function |
Actual time (max. 24 Hrs.), integration time (max. 49999 Hrs.), |
Clock, Calibration off-set |
Timer |
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. Digital setting, |
Heater circuit control |
Triac zero cross method |
Safe Device |
|
Self diagnosis functions (Temp. sensor, Heater, Triac, Automatic overheating prevention), Key lock function, Independent over heating prevention, Electric leakage breaker. |
Standard |
Internal dimensions (mm) |
100×150×100 |
200×250×150 |
300×250×150 |
External dimensions (W×D×Hmm) |
376×405×517 |
446×504×567 |
507×504×626 |
Internal capacity |
1.5L |
7.5L |
11.3L |
Power source |
AC 100V |
AC 100V |
Single phase AC 200V |
Single phase AC200V |
50/60Hz |
11A (15A) |
24A (30A) |
12A(15A) |
16.5A (20A) |
Weight |
Approx.24kg |
Approx.42kg |
Approx.48kg |
Accessories |
Exhaust port cap |
Fuse |
1pc |
2pcs |
1pc |
2pcs |
|
|
Control Panel |
 |
Optional Items |
Description |
Model No. |
Product Code |
Exhaust unit, 100V |
FP101, 301 |
214096 |
Exhaust unit, 200V |
FP311, 411 |
214097 |
Time up output terminal |
FP Series |
214193 |
External alarm terminal |
FP Series |
214195 |
Temp. output terminal (4-20mA) |
FP Series |
214194 |
N2 gas inlet system with flow meter |
FP101 |
214196 |
FP301/311 |
214197 |
FP411 |
214198 |
Sample tray |
FP Series |
281310 |
External Communication Adapter (RC23) |
FP Series |
281311 |
|
|
Exhaust unit (option) |
Gas which generated due to the increase of temperature in the furnace will be quickly exhausted
Duct: Flexible duct, aluminum type
Length: 1.5m
50mm diameter
Power of exhaust device :
AC100V 0.27A Single phase AC200V 0.15A |
 |
Dimension drawing (mm) |
 |
|